Summary for Test 2025-06-12-106-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001159 DEA: 043X2804 EFIS: 0425000226 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-121- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Apply traffic control systems, perform digout, install earth retaining structures |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/07/2025) |
Sample Information
| Sample Taken Date | 06/12/2025 | Sample Unique Key | 106 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4"HMA25%RapWMA |
| The quantity of what the sample constitutes | 100Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Christian | Last name of sampler or witnessed by | Sousa |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Napa | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-06-12-106
DIME Test ID: 2025-06-12-106-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-21
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry comcepcion
Date of test: 07/02/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2254.8 g
Mass Loss: 129.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.70 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.11 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.92 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2025 ✔