Summary for Test 2025-07-03-2-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 993678 DEA: 042Q8004 EFIS: 0419000050 COOP: 042836,042944 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101,92-US 101 & SR 92-10.9/12.1 & 11.8/13.4 |
| Award Date | 01/22/2025 |
| Closeout Date | Not set |
| Work Description | US 101/SR 92 INTERCHANGE AREA IMPROVEMENT :PROJECT WILL CONSTRUCT CONGESTION RELIEF IMPROVEMENTS AT THE US 101/SR 92 INTERCHANGE AREA. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/15/2022) |
Sample Information
| Sample Taken Date | 07/03/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/08/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #8 (25mm) 5'-2" Welded Hoops |
| The quantity of what the sample constitutes | 320 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Adrian | Last name of sampler or witnessed by | Sanchez |
| Title of sampler | Telephone number of sampler | 2137133499 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L159-092-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1202067394 |
| Hoop Manufacturer Lot Number(s) | Lot 1-3 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #8 |
| Diameter of Hoop | 5'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | NUCOR |
| Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2025-07-03-2
DIME Test ID: 2025-07-03-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)
Test Release Date: 2025-07-22
Test Results
Necking Test Option: Necking Test Option I
Shape of the Sample: Hoop
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/21/2025
Sample 1 Visible Necking?: Yes
Sample 1 Location of Fracture?: Bar
Sample 2 Visible Necking?: Yes
Sample 2 Location of Fracture?: Bar
Sample 3 Visible Necking?: Yes
Sample 3 Location of Fracture?: Bar
Sample 4 Visible Necking?: Yes
Sample 4 Location of Fracture?: Bar
General comments (publicly viewable) (Max 1000 characters): Lot #3
Test was verified on 7/22/2025 ✔