Summary for Test 2025-07-14-2-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994816 DEA: 010E11U4 EFIS: 0123000069 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-1-31.1/31.6 |
| Award Date | 11/15/2023 |
| Closeout Date | Not set |
| Work Description | STRUCTURAL CONC BRIDGE, TEMP BRIDGE AND BAR REINFORCING STEEL. |
| Location Description | MENDOCINO COUNTY NEAR ELK FROM 0.2 MILE SOUTH OF ELK CREEK BRIDGE TO 0.2 MILE NORTH OF ELK CREEK BRIDGE |
| QA Service Level | 1 (Verified on 05/22/2023) |
Sample Information
| Sample Taken Date | 07/14/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/16/2025 | Sample type | Quality Assurance |
| A brief description of the sample | Couplers with #11 bar, Grade 80 | The quantity of what the sample constitutes | 1 lot of 48 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Stacey |
| Last name of sampler or witnessed by | Davis | Title of sampler | QAI |
| Telephone number of sampler | 5624806984 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Tracy | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S86-024-25 | |
| Structure unique identifier | 10-0312 | Structure name | Elk Creek Bridge |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 80 | Rebar Manufacturer | CMC Mesa |
| Coupler Manufacturer | HRC Gerdau | Intermediate Assembler or Fabricator | CMC Tracy |
| Rebar Size | #11 | Coupler Model | Extender 500 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 74126669 | Rebar Heat Number(s) | 9004339 |
| Rebar Size 2 | Coupler Unique ID | TF-17-02 |
Test Details
DIME Sample ID: 2025-07-14-2
DIME Test ID: 2025-07-14-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-07-22
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/21/2025
UTM: NA
Halo ID: NA
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 74126669 | 11 | 1.56 | 0.0007 | 175710 | 112635 | NA | Miguel Baltazar |
| 2 | 2 | 74126669 | 11 | 1.56 | 0 | 175770 | 112673 | NA | Miguel Baltazar |
| 3 | 3 | 74126669 | 11 | 1.56 | 0 | 175050 | 112212 | NA | Miguel Baltazar |
| 4 | 4 | 74126669 | 11 | 1.56 | 0 | 174820 | 112064 | NA | Miguel Baltazar |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/22/2025 ✔