Summary for Test 2025-07-02-14-7
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/02/2025 | Sample Unique Key | 14 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/08/2025 | Sample type | Quality Assurance |
| A brief description of the sample | A325 Bolt | The quantity of what the sample constitutes | 595 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Joe |
| Last name of sampler or witnessed by | Barron | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AFC Industries | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 10900260 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
| Bolt Length(s) | 3-1/4 | Nut Specification | NA |
| Washer Specification | NA | Finish | HDG |
| Diameter/Size | 1-1/4 | Bolt Mfg. Lot Number | E327R1 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-07-02-14
DIME Test ID: 2025-07-02-14-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2025-07-24
Test Results
Number of Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/21/2025
UTM: NA
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | E327R1 | 1.25 | 139530 | 0 | NA | W Torres |
| 2 | 1B | E327R1 | 1.25 | 134180 | 0 | NA | W Torres |
| 3 | 1C | E327R1 | 1.25 | 141660 | 0 | NA | W Torres |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/24/2025 ✔