Summary for Test 2025-07-17-37-2

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000541
DEA: 09374704
EFIS: 0918000019
DIST-CO-RTE-PM09-INY-168,395-17.6/18.3,114.9/117.8
Award Date02/21/2025
Closeout DateNot set
Work DescriptionHMA (TYPE A), MINOR CONCRETE, AND LIGHTING.
Location DescriptionINYO COUNTY IN AND NEAR BISHOP ON ROUTE 395 FROM 0.1 MILE SOUTH OF JAY STREET TO BARLOW LANE AND ON ROUTE 168 FROM PIONEER LANE TO ROUTE 395
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date07/17/2025 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2025
Sample typeProduction Start-Up A brief description of the sample3/4" Coldfeed & RAP
The quantity of what the sample constitutes85 Tons From where was the sample collectedSource
First name of sampler or witnessed byDylan Last name of sampler or witnessed byCarapazza
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationPSU-1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite 5 Bridges Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)00-00-0000
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample Device at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-07-17-37
DIME Test ID: 2025-07-17-37-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-07-21

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 07/17/2025
Cumulative Percent Passing
0 %
100 %
100 %
93 %
81 %
75 %
57 %
41 %
29 %
21 %
13 %
7 %
4.2 %
General comments (publicly viewable) (Max 1000 characters): PSU-1 Gradation with RAP

Test was verified on 7/21/2025