Summary for Test 2025-07-16-11-3
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 1000682 DEA: 09379104 EFIS: 0919000005 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-91.6/100.8 |
| Award Date | 02/20/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS. |
| Location Description | INYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168 |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 07/16/2025 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2025 |
| Sample type | Quality Assurance | A brief description of the sample | THMA-4 |
| The quantity of what the sample constitutes | 750 to 1500 Tons | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jerid | Last name of sampler or witnessed by | Kupelian |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | RHB Plant Independence | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 4 | HMA Mix Number | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-07-16-11
DIME Test ID: 2025-07-16-11-3
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2025-07-21
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 07/16/2025
| Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1719.3 grams | ||||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 81.2 grams | -0.8 % | 94 % | ||||
| 122.6 grams | -0.5 % | 92 % | ||||
| 742.1 grams | -0.5 % | 56 % | ||||
| 1019.5 grams | -0.2 % | 41 % | ||||
| 1224.8 grams | -0.3 % | 28 % | ||||
| 1379.0 grams | 0.0 % | 20 % | ||||
| 1508.7 grams | -0.4 % | 12 % | ||||
| 1601.0 grams | -0.1 % | 7 % | ||||
| 1653.5 grams | 1.6 % | 5.4 % | ||||
| 1666.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters): HMA-T4 PP Gradation
Test was verified on 7/21/2025 ✔