Summary for Test 2025-07-08-40-2
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 993454 DEA: 040K8004 EFIS: 0416000141 COOP: 042892 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-13.7 |
| Award Date | 02/05/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT ROUNDABOUT, CURB RAMPS AND SW, SIGNAL AND LIGHTING SYSTEMS. |
| Location Description | MARIN COUNTY IN SAN RAFAEL AT FREITAS PARKWAY OVERCROSSING |
| QA Service Level | 1 (Verified on 12/10/2021) |
Sample Information
| Sample Taken Date | 07/08/2025 | Sample Unique Key | 40 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Structural Backfill |
| The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
| Title of sampler | CONSULTANT TECH | Telephone number of sampler | 5102077252 |
| Laboratory sample identification | Rich_25_298 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Eco Terra / Richmond | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Class 2 AB Recycle |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Job site | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-07-08-40
DIME Test ID: 2025-07-08-40-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-07-18
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/08/2025
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 0 % | ||||||
| 0 % | ||||||
| 35 % | ||||||
| 24 % | ||||||
| 16 % | ||||||
| 10 % | ||||||
| 6 % | ||||||
| 4 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Fine Gradation for Clas 2 AB Recycle from Eco-terra /Richmond
Test was verified on 7/18/2025 ✔