Summary for Test 2025-07-08-40-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 993454
DEA: 040K8004
EFIS: 0416000141
COOP: 042892
DIST-CO-RTE-PM04-MRN-101-13.7
Award Date02/05/2025
Closeout DateNot set
Work DescriptionCONSTRUCT ROUNDABOUT, CURB RAMPS AND SW, SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionMARIN COUNTY IN SAN RAFAEL AT FREITAS PARKWAY OVERCROSSING
QA Service Level1 (Verified on 12/10/2021)

Sample Information

Sample Taken Date07/08/2025 Sample Unique Key40
Date that the sample was received by the laboratory/organization performing the testing07/17/2025 Sample typeQuality Assurance
A brief description of the sampleStructural Backfill The quantity of what the sample constitutes2 bags
From where was the sample collectedJob Site First name of sampler or witnessed byIGNACIO
Last name of sampler or witnessed byARECHIGA Title of samplerCONSULTANT TECH
Telephone number of sampler5102077252 Laboratory sample identificationRich_25_298
Linked DIME Sample ID The fabricator/manufacturer/facility nameEco Terra / Richmond
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleClass 2 AB Recycle
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedJob site
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-07-08-40
DIME Test ID: 2025-07-08-40-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-07-18

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/18/2025
Sieve SizeCumulative Percent Passing
0 %
0 %
96 %
83 %
73 %
50 %
0 %
General comments (publicly viewable) (Max 1000 characters): Coarse side of Class 2 Recycle AB

Test was verified on 7/18/2025 ✔