Summary for Test 2025-07-12-1-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001312 DEA: 11432844 EFIS: 1125000219 |
|---|---|
| DIST-CO-RTE-PM | 11--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/12/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2025 |
| Sample type | Production Start-Up | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 12 Boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-07-12-1-PSU | Linked DIME Sample ID | 2025-07-12-2 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1-1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 820801 Otay Val | |
| Binder content (%) | 3.9 | Virgin binder PG | PG 70-10 |
| Design binder PG | PG 70-10 | Binder Supplier | Valero |
| RAP content (%) | 22 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2025-07-12-1
DIME Test ID: 2025-07-12-1-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-22
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/18/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4014.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 8051.0 g
Mass of HMA Sample prior to ignition: 4036.5 g
Mass Loss: 187.5 g
Mass of aggregate remaining after ignition: 3849.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.25 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.40 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 3.9% Tested 4.00%
Test was verified on 7/22/2025 ✔
