Summary for Test 2025-07-09-34-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date07/09/2025 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing07/10/2025 Sample typeQuality Assurance
A brief description of the sampleJMFV The quantity of what the sample constitutes12 boxes
From where was the sample collectedSource First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byCordero Title of samplerTET
Telephone number of sampler6199366795 Laboratory sample identification25-07-09-34-JMFV
Linked DIME Sample ID2025-07-09-35 The fabricator/manufacturer/facility nameMartin Marietta
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21218180
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-07-09-34
DIME Test ID: 2025-07-09-34-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-22

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/18/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4034.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 5590.5 g
Mass of HMA Sample prior to ignition: 1556.3 g
Mass Loss: 132.8 g
Mass of aggregate remaining after ignition: 1423.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.20 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.33 %
General comments (publicly viewable) (Max 1000 characters): Target - 7.5%, Save Material for T30

Test was verified on 7/22/2025 ✔