Summary for Test 2025-07-09-45-8
Test performed: CTM 389-19
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
| Project Identifiers | Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-78-N17.7 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical. |
| Location Description | IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING. |
| QA Service Level | 1 (Verified on 05/07/2025) |
Sample Information
| Sample Taken Date | 07/09/2025 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/11/2025 |
| Sample type | Verification | A brief description of the sample | JMFV |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-07-09-45-JMFV | Linked DIME Sample ID | 2025-07-09-46 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 23418180 MM | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-07-09-45
DIME Test ID: 2025-07-09-45-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-07-22
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/21/2025
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 1 mm
Maximum impression at 5000 passes (right wheel): 1 mm
Average impression at 5000 passes (left/right avg): 1 mm
Maximum impression at 10000 passes (left wheel): 1 mm
Maximum impression at 10000 passes (right wheel): 1 mm
Average impression at 10000 passes (left/right avg): 1 mm
Maximum impression at 15000 passes (left wheel): 1 mm
Maximum impression at 15000 passes (right wheel): 1 mm
Average impression at 15000 passes (left/right avg): 1 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/22/2025 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.