Summary for Test 2025-07-09-45-8

Test performed: CTM 389-19
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date07/09/2025 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/11/2025
Sample typeVerification A brief description of the sampleJMFV
The quantity of what the sample constitutes12 boxes From where was the sample collectedSource
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of samplerTET Telephone number of sampler6199366795
Laboratory sample identification25-07-09-45-JMFV Linked DIME Sample ID2025-07-09-46
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number23418180 MM
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-09-45
DIME Test ID: 2025-07-09-45-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-07-22

Test Results


Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/21/2025
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 1 mm
Maximum impression at 5000 passes (right wheel): 1 mm
Average impression at 5000 passes (left/right avg): 1 mm
Maximum impression at 10000 passes (left wheel): 1 mm
Maximum impression at 10000 passes (right wheel): 1 mm
Average impression at 10000 passes (left/right avg): 1 mm
Maximum impression at 15000 passes (left wheel): 1 mm
Maximum impression at 15000 passes (right wheel): 1 mm
Average impression at 15000 passes (left/right avg): 1 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/22/2025

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.