Summary for Test 2025-07-14-44-5

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 993253
DEA: 033F0604
EFIS: 0312000052
DIST-CO-RTE-PM03-GLE-162-76.3/78.6
Award Date02/02/2022
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date07/14/2025 Sample Unique Key44
Date that the sample was received by the laboratory/organization performing the testing07/14/2025 Sample typeProduction Start-Up
A brief description of the sample2 Boxes The quantity of what the sample constitutes3/4" RHMA-G
From where was the sample collectedSource First name of sampler or witnessed byMark
Last name of sampler or witnessed byAtterberry Title of samplerTET
Telephone number of sampler Laboratory sample identificationPSU 25-101
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Hallwood
Transportation Laboratory (TL) NumberC778842 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-14-44
DIME Test ID: 2025-07-14-44-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-07-17

Test Results


Specified number of passes at 12.7 mm: 25000
Specimen Preparation Method: PMLC
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 07/16/2025
Average impression at 5000 passes (left/right avg): 1.48 mm
Average impression at 10000 passes (left/right avg): 1.805 mm
Average impression at 15000 passes (left/right avg): 2.125 mm
Average impression at 20000 passes (left/right avg): 2.335 mm
Average impression at 25000 passes (left/right avg): 2.59 mm
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/17/2025 ✔