Summary for Test 2025-07-13-3-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000900
DEA: 061G1804
EFIS: 0623000159
DIST-CO-RTE-PM06-KER-5-Var
Award Date03/19/2025
Closeout DateNot set
Work DescriptionFURNISH AND PLACE POLYESTER CONCRETE OVERLAY.
Location DescriptionKERN COUNTY AT VARIOUS LOCATIONS FROM GRAPEVINE CREEK BRIDGE TO KERN RIVER FLOOD CANAL BRIDGE
QA Service Level1 (Verified on 01/22/2025)

Sample Information

Sample Taken Date07/13/2025 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2025
Sample typeAcceptance A brief description of the sampleISR (RSC)
The quantity of what the sample constitutes0-130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMike Last name of sampler or witnessed byCozad
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS SHORT LOAD RAPID SET Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedVolumetric Mixer Where the material sample would have been placed if not samplediSR
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-07-13-3
DIME Test ID: 2025-07-13-3-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-07-17

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Mike Cozad
Date of test: 07/17/2025
Identification number: 118
Width of specimen: 6.0625 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7740 lb
Maximum load applied 2: 7400 lb
Maximum load applied 3: 7230 lb
Curing history and apparent moisture condition of the specimen: Good
If specimen was capped, ground or if leather shims were used: leather shims were used
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 3 days
Age of specimen in hours: 4 hours
Modulus of rupture: 660 psi
Modulus of rupture 2: 620 psi
Modulus of rupture 3: 600 psi
Modulus of rupture average: 630 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-1G1804_37023_250713_3Dpdf112.59 KB07/17/20252025-07-13-3-1   Info

Test was verified on 7/17/2025