Summary for Test 2025-05-19-94-5
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 994609 DEA: 112N1194 EFIS: 1121000148 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-94-14.9/29.2 |
| Award Date | 05/18/2023 |
| Closeout Date | 05/06/2025 |
| Work Description | MICROSURFACING, RUMBLE STRIP, PAVEMENT MARKING, & SHOULDER BACKING. |
| Location Description | SAN DIEGO COUNTY NEAR JAMUL FROM JUNCTION ROUTE 54/94 TO 0.7 MILE EAST OF DULZURA CREEK |
| QA Service Level | 1 (Verified on 08/23/2023) |
Sample Information
| Sample Taken Date | 05/19/2025 | Sample Unique Key | 94 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2025 |
| Sample type | Verification | A brief description of the sample | Emulsion- MSE |
| The quantity of what the sample constitutes | 2qt, one container | From where was the sample collected | Source |
| First name of sampler or witnessed by | NO ASSIGNED | Last name of sampler or witnessed by | NO ASSIGNED |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | DISTRIBTOR TRUCK | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | N/A |
Test Details
DIME Sample ID: 2025-05-19-94
DIME Test ID: 2025-05-19-94-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2025-07-17
Test Results
Is Correction factor required?: Yes
Input Type: Calculated
Tester's full name: Hussaya Leelakitrungruang
Date of test: 06/02/2025
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 1048.0 sec
Efflux time for determination of the correction factor (ETCF1): 1.0 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 1.0 sec
Correction Factor (F): 1.0 sec
Efflux time (ET) for test sample: 18.7 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 1048 sec
Test efflux temperature: 77 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2025 ✔