Summary for Test 2025-07-15-17-7

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 1000682
DEA: 09379104
EFIS: 0919000005
DIST-CO-RTE-PM09-INY-395-91.6/100.8
Award Date02/20/2025
Closeout DateNot set
Work DescriptionCONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS.
Location DescriptionINYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date07/15/2025 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2025
Sample typeProduction Start-Up A brief description of the sample1/2" HMA-A-SP PG58-34M R18
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byJerid Last name of sampler or witnessed byKupelian
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationT-PSU-1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRHB Plant Independence Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-07-15-17
DIME Test ID: 2025-07-15-17-7
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2025-07-16

Test Results


Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 07/16/2025
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 20 mm
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 5.91 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 5.73 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
General comments (publicly viewable) (Max 1000 characters): PSU-T1

Test was verified on 7/16/2025