Summary for Test 2025-05-03-7-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000602
DEA: 040K6404
EFIS: 0416000112
DIST-CO-RTE-PM04-SOL-80-15.9/30.2
Award Date12/17/2024
Closeout DateNot set
Work DescriptionCOLD PLANE, OVERLAY, MGS, RAMP METERING, LIGHTING AND SIGNAL.
Location DescriptionSOLANO COUNTY ON ROUTE 80 IN AND NEAR FAIRFIELD AND VACAVILLE AT VARIOUS LOCATIONS FROM 1.5 MILES EAST OF SUISUN VALLEY ROAD OVERCROSSING TO 0.8 MILE EAST OF LEISURE TOWN ROAD OVERCROSSING.
QA Service Level1 (Verified on 10/07/2024)

Sample Information

Sample Taken Date05/03/2025 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2025
Sample typeQuality Assurance A brief description of the sample3/4 HMA
The quantity of what the sample constitutes100Tons From where was the sample collectedJob Site
First name of sampler or witnessed byDrew Last name of sampler or witnessed byWidler
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Aggregates Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number3 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-03-7
DIME Test ID: 2025-05-03-7-4
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-15

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Concepcion
Date of test: 05/29/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2101.4 g
Mass Loss: 125.9 g
Correction Factor (Percent by mass of HMA Specimen): 1.01 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.86 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/15/2025