Summary for Test 2025-07-14-22-1

Test performed: ASTM C136-19

Project Information

Project IdentifiersProject ID: 1000697
DEA: 021J75U4
EFIS: 0224000092
DIST-CO-RTE-PM02-LAS-36-14.4/R16.8
Award Date01/23/2025
Closeout DateNot set
Work DescriptionPLACE HMA AND CLASS 2 AB, EXCAVATE ROADWAY, & INSTALL LIGHTING SYSTEM.
Location DescriptionLASSEN COUNTY ABOUT 9 MILES WEST OF SUSANVILLE FROM 1.3 MILES WEST TO 1.2 MILES EAST OF WILLARD CREEK ROAD
QA Service Level1 (Verified on 10/24/2024)

Sample Information

Sample Taken Date07/14/2025 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing07/14/2025 Sample typeQuality Control
A brief description of the sampleConcrete Aggregate The quantity of what the sample constitutes25 tons
From where was the sample collectedSource First name of sampler or witnessed byBrian
Last name of sampler or witnessed byFoley Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameStructureCast
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Vulcan San Emidio
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStructuecast
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-07-14-22
DIME Test ID: 2025-07-14-22-1
Testing Lab: Structure Cast
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-07-15

Test Results


What type of gradation is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Has the fine aggregate sample been reduced? (question for combined gradation type): No
Input Type: Calculated
Tester's full name: Brian Foley
Date of test: 07/14/2025
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 89 %
Cumulative percent passing the #4 sieve: 22 %
Cumulative percent passing the #8 sieve: 7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/15/2025 ✔