Summary for Test 2025-07-14-18-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000900
DEA: 061G1804
EFIS: 0623000159
DIST-CO-RTE-PM06-KER-5-Var
Award Date03/19/2025
Closeout DateNot set
Work DescriptionFURNISH AND PLACE POLYESTER CONCRETE OVERLAY.
Location DescriptionKERN COUNTY AT VARIOUS LOCATIONS FROM GRAPEVINE CREEK BRIDGE TO KERN RIVER FLOOD CANAL BRIDGE
QA Service Level1 (Verified on 01/22/2025)

Sample Information

Sample Taken Date07/14/2025 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/15/2025
Sample typeAcceptance A brief description of the sampleiSR (RSC)
The quantity of what the sample constitutes0-300 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMike Last name of sampler or witnessed byCozad
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS SHORT LOAD RAPID SET Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedVolumetric Truck
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberCTS-65-EHI Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-07-14-18
DIME Test ID: 2025-07-14-18-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-07-15

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Mike Cozad
Date of test: 07/15/2025
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
10518.5 grams
0.0 grams100 %
200.0 grams98 %
1872.0 grams82 %
6935.5 grams34 %
9008.5 grams14 %
10321.5 grams2 %
10416.4 grams1 %
10506.5 grams
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-1G1804_37023_250714pdf130.96 KB07/15/20252025-07-14-18-1   Info

Test was verified on 7/15/2025