Summary for Test 2025-01-06-57-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 993825
DEA: 040Q30U4
EFIS: 0420000235
COOP: 042830A3,042830A4
DIST-CO-RTE-PM04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9
Award Date11/23/2022
Closeout DateNot set
Work DescriptionPRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date01/06/2025 Sample Unique Key57
Date that the sample was received by the laboratory/organization performing the testing05/28/2025 Sample typeAnnual Source Testing
A brief description of the sample1 x 4 PCC Aggregate The quantity of what the sample constitutes2 Bags
From where was the sample collectedSource First name of sampler or witnessed byDennis
Last name of sampler or witnessed byYeung Title of sampler
Telephone number of sampler Laboratory sample identification1281
Linked DIME Sample ID The fabricator/manufacturer/facility nameDeSilva Gates Sunol
Transportation Laboratory (TL) NumberC010625 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-01-06-57
DIME Test ID: 2025-01-06-57-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2025-07-14

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: David Padilla
Date of test: 06/23/2025
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: 3.8 %
Percentage Loss of material retained on ¾ x ½ in. sieve: 6.0 %
Percentage Loss of material retained on ½ x ⅜ in. sieve: 4.9 %
Percentage Loss of material retained on ⅜ in. x #4 sieve: 7.1 %
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 5.3 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters): Sample tested at SRL due to Translab shutdown

Test was verified on 7/14/2025 ✔