Summary for Test 2025-06-11-41-5
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-37.4-52.6 |
| Award Date | 10/20/2023 |
| Closeout Date | Not set |
| Work Description | I-5 NCC SEGMENT 4C |
| Location Description | I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing |
| QA Service Level | 1 (Verified on 11/20/2023) |
Sample Information
| Sample Taken Date | 06/11/2025 | Sample Unique Key | 41 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2025 |
| Sample type | Quality Assurance | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-06-11-41-PSU | Linked DIME Sample ID | 2025-06-11-42 |
| The fabricator/manufacturer/facility name | Vulcan | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 320819 CC SJR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-06-11-41
DIME Test ID: 2025-06-11-41-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2025-07-11
Test Results
Unit system used?: SI Units
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/11/2025
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Untreated | ||||||
| 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | |
| 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | |
| 3719.3 g | 3718.5 g | 3720.4 g | 3722.1 g | 3721.5 g | 3720.5 g | |
| 2099.1 g | 2099.2 g | 2098.2 g | 2099.8 g | 2097.2 g | 2099.2 g | |
| 3727.5 g | 3724.9 g | 3730.1 g | 3730.2 g | 3727.0 g | 3727.6 g | |
| 2.459 | 2.459 | 2.459 | 2.459 | 2.459 | 2.459 | |
| 3800.2 g | 3798.2 g | 3803.8 g | ||||
| 2099.1 g | 2099.2 g | 2098.2 g | ||||
| 95.1 mm | 95.1 mm | 95.1 mm | ||||
| 225 mmHg | 225 mmHg | 225 mmHg | ||||
| 0 inHg | 0 inHg | 0 inHg | ||||
| 5 minutes | 5 minutes | 5 minutes | ||||
1628.4 cm^3 | 1625.7 cm^3 | 1631.9 cm^3 | 1630.4 cm^3 | 1629.8 cm^3 | 1628.4 cm^3 | |
2.284 | 2.287 | 2.280 | 2.283 | 2.283 | 2.285 | |
7.1 % | 7.0 % | 7.3 % | 7.2 % | 7.2 % | 7.1 % | |
115.6 cm^3 | 113.8 cm^3 | 119.1 cm^3 | 117.4 cm^3 | 117.3 cm^3 | 115.6 cm^3 | |
3800.2 g | 3798.2 g | 3803.8 g | ||||
3811.8 g | 3809.5 g | 3815.7 g | ||||
1701.1 cm^3 | 1699.0 cm^3 | 1705.6 cm^3 | ||||
80.9 cm^3 | 79.7 cm^3 | 83.4 cm^3 | ||||
70 % | 70 % | 70 % | ||||
4.5 % | 4.5 % | 4.5 % | ||||
16236 N | 20231 N | 15791 N | 22722 N | 22268 N | 23081 N | |
1 | 1 | 1 | 1 | 1 | 1 | |
1 | 1 | 1 | 1 | 1 | 1 | |
1 | 1 | 1 | 1 | 1 | 1 | |
725 kPa | 903 kPa | 705 kPa | 1015 kPa | 995 kPa | 1031 kPa | |
113 psi | 147 psi | |||||
0.77 | ||||||
General comments (publicly viewable) (Max 1000 characters): Complies Target WET> 70 psi and DRY > 100 psi Tested WET 113 psi and DRY 147 psi
Test was verified on 7/11/2025 ✔