Summary for Test 2025-06-19-49-5

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 994535
DEA: 010H8404
EFIS: 0118000117
DIST-CO-RTE-PM01-LAK-20-2.0/2.8
Award Date07/21/2023
Closeout DateNot set
Work DescriptionRDWY EXC, PLACE HMA-A & RHMA, CONST SOLDIER PILE & RETAINING WALLS.
Location DescriptionLAKE COUNTY ABOUT 6 MILES WEST OF UPPER LAKE FROM 0.6 MILE WEST OF IRVINE AVENUE TO 0.1 MILE EAST OF MID LAKE ROAD
QA Service Level1 (Verified on 04/25/2023)

Sample Information

Sample Taken Date06/19/2025 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing06/25/2025 Sample typeQuality Assurance
A brief description of the samplePG 58-22 The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byDamien
Last name of sampler or witnessed byD Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Ukiah
Transportation Laboratory (TL) Number778804 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-06-19-49
DIME Test ID: 2025-06-19-49-5
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-07-11

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/09/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 208.704 grams
Mass of container #2 before test (m2i): 209.219 grams
Mass of container #1 after test (m1f): 208.488 grams
Mass of container #2 after test (m2f): 209.006 grams
Mass of empty container #1: 173.288 grams
Mass of empty container #2: 174.529 grams
Mass correction factor: 0.030
Average mass change: -0.582 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change

Test was verified on 7/11/2025 ✔