Summary for Test 2025-07-10-20-2
Test performed: CTM 216-June 2011Project Information
| Project Identifiers | Project ID: 1000301 DEA: 07333704 EFIS: 0716000316 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-138-43.4/51.4 |
| Award Date | 07/30/2024 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT ADA CURB RAMPS, SIDEWALK, AND DRIVEWAY. |
| Location Description | LOS ANGELES COUNTY IN PALMDALE FROM ROUTE 14 JUNCTION (SOUTH) TO AVENUE T |
| QA Service Level | 1 (Verified on 08/12/2024) |
Sample Information
| Sample Taken Date | 07/10/2025 | Sample Unique Key | 20 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/10/2025 | Sample type | Acceptance |
| A brief description of the sample | Aggregate Base | The quantity of what the sample constitutes | 500 SF |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Michelangelo |
| Last name of sampler or witnessed by | Sese | Title of sampler | TET |
| Telephone number of sampler | 310-345-6204 | Laboratory sample identification | 25-2217 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | NA | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Aggregate Base |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Various locations | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-07-10-20
DIME Test ID: 2025-07-10-20-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2025-07-10
Test Results
Is oversize material: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 07/10/2025
In-place wet density: 1.98
Highest adjust wet density: 2.06
% Moisture: 12.5 %
Optimum Moisture: no data
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters): CA Rte. 138 Curb Ramp #34
Intersection of Palmdale Blvd & 30th St
Test was verified on 7/10/2025 ✔