Summary for Test 2025-05-02-44-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000905
DEA: 120V0004
EFIS: 1224000066
DIST-CO-RTE-PM12-ORA-261-3.5/6.2
Award Date03/12/2025
Closeout Date08/29/2025
Work DescriptionCOLD PLANE AND OVERLAY WITH RUBBERIZED HOT MIX ASPHALT.
Location DescriptionORANGE COUNTY IN IRVINE AND ORANGE FROM 0.6 MILE NORTH OF PORTOLA PARKWAY OVERCROSSING TO JUNCTION ROUTE 241
QA Service Level1 (Verified on 01/23/2025)

Sample Information

Sample Taken Date05/02/2025 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/02/2025
Sample typeQuality Assurance A brief description of the sample1/2 RWMAG
The quantity of what the sample constitutes1/2 RWMAG From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed byNguyen
Title of sampler Telephone number of sampler
Laboratory sample identification25-0423 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-05-02-44
DIME Test ID: 2025-05-02-44-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-25

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 05/05/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4030.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5566.2 g
Mass of HMA Sample prior to ignition: 1535.6 g
Mass Loss: 109.2 g
Mass of aggregate remaining after ignition: 1426.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.34 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.77 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
2025AC-SP-0030pdf105.45 KB07/10/20252025-05-02-44-2   Info

Test was verified on 7/25/2025