Summary for Test 2025-06-08-14-1

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 1000509
DEA: 010H6004
EFIS: 0117000240
DIST-CO-RTE-PM01-MEN-1-33.7/R51.0
Award Date11/25/2024
Closeout DateNot set
Work DescriptionHMA, RHMA, COLD PLANE, GUARDRAIL, AND DELINEATION.
Location DescriptionMENDOCINO COUNTY NEAR ELK FROM 0.1 MILE NORTH OF GREENWOOD CREEK BRIDGE TO 0.2 MILE NORTH OF LITTLE LAKE ROAD AT MENDOCINO
QA Service Level1 (Verified on 09/20/2024)

Sample Information

Sample Taken Date06/08/2025 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/17/2025
Sample typeVerification A brief description of the samplePG 58-22 "JMF"
The quantity of what the sample constitutes1 Quart From where was the sample collectedSource
First name of sampler or witnessed byFelipe Last name of sampler or witnessed byDamian
Title of samplerConsultant Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite - Ukiah Transportation Laboratory (TL) NumberC778801
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierGranite Ukiah
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-06-08-14
DIME Test ID: 2025-06-08-14-1
Testing Lab: Atlas - Denver
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-07-09

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/01/2025
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.06 %
Stress Amplitude: 0.147 kPa
Phase Angle (δ) (for the 10 cycles): 87.1 degree
Complex Modulus (G*) (for the 10 measurements): 1.221 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 1.22 kPa
General comments (publicly viewable) (Max 1000 characters): Original

Test was verified on 7/9/2025