Summary for Test 2025-05-20-88-2
Test performed: AASHTO T315-24Project Information
| Project Identifiers | Project ID: 1000414 DEA: 034H8704 EFIS: 0319000070 |
|---|---|
| DIST-CO-RTE-PM | 03-SUT-99-25.0/26.2 |
| Award Date | 10/09/2024 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, PLACE HMA-A AND CRCP, INSTALL SIGNAL AND LIGHTING. |
| Location Description | SUTTER COUNTY NEAR YUBA CITY FROM 0.6 MILE SOUTH TO 0.6 MILE NORTH OF OSWALD ROAD |
| QA Service Level | 1 (Verified on 07/30/2024) |
Sample Information
| Sample Taken Date | 05/20/2025 | Sample Unique Key | 88 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/11/2025 | Sample type | Quality Assurance |
| A brief description of the sample | PG 64-16 binder | The quantity of what the sample constitutes | 1 Can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | McKeehan | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Hallwood | |
| Transportation Laboratory (TL) Number | C778931 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2025-05-20-88
DIME Test ID: 2025-05-20-88-2
Testing Lab: Atlas - Denver
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-07-09
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/01/2025
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.05 %
Stress Amplitude: 0.269 kPa
Phase Angle (δ) (for the 10 cycles): 83.8 degree
Complex Modulus (G*) (for the 10 measurements): 2.672 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.69 kPa
General comments (publicly viewable) (Max 1000 characters): RTFO
Test was verified on 7/9/2025 ✔