Summary for Test 2025-06-27-25-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000117 DEA: 020J0104 EFIS: 0219000044 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-99-4.2/4.8 |
| Award Date | 07/11/2024 |
| Closeout Date | Not set |
| Work Description | PLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM. |
| Location Description | TEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD |
| QA Service Level | 1 (Verified on 03/18/2024) |
Sample Information
| Sample Taken Date | 06/27/2025 | Sample Unique Key | 25 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/01/2025 |
| Sample type | Acceptance | A brief description of the sample | 3/4" HMA-A |
| The quantity of what the sample constitutes | 2 box HMA | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | White |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | D79937 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Knife River, Orland | Transportation Laboratory (TL) Number | 858141 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-06-27-25
DIME Test ID: 2025-06-27-25-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-09
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Sean McWithey
Date of test: 07/07/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3153.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 5213.2 g
Mass of HMA Sample prior to ignition: 2060.1 g
Mass Loss: 112.0 g
Mass of aggregate remaining after ignition: 1948.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.79 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.50 %
General comments (publicly viewable) (Max 1000 characters): Pb=4.50%
Test was verified on 7/9/2025 ✔