Summary for Test 2025-06-27-25-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1000117 DEA: 020J0104 EFIS: 0219000044 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-99-4.2/4.8 |
| Award Date | 07/11/2024 |
| Closeout Date | Not set |
| Work Description | PLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM. |
| Location Description | TEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD |
| QA Service Level | 1 (Verified on 03/18/2024) |
Sample Information
| Sample Taken Date | 06/27/2025 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/01/2025 | Sample type | Acceptance |
| A brief description of the sample | 3/4" HMA-A | The quantity of what the sample constitutes | 2 box HMA |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Brandon |
| Last name of sampler or witnessed by | White | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D79937 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Knife River, Orland | |
| Transportation Laboratory (TL) Number | 858141 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-06-27-25
DIME Test ID: 2025-06-27-25-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-07-09
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/02/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7334 grams
Mass of oven-dry sample in air for Sample 1: 2567.1 grams
Mass of container filled with the sample and water for Sample 1: 8903.4 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.573
Theoretical maximum density at 25°C (77°F): 2565.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.573
Test was verified on 7/9/2025 ✔