Summary for Test 2025-06-27-23-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000117
DEA: 020J0104
EFIS: 0219000044
DIST-CO-RTE-PM02-TEH-99-4.2/4.8
Award Date07/11/2024
Closeout DateNot set
Work DescriptionPLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location DescriptionTEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date06/27/2025 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/30/2025
Sample typeAcceptance A brief description of the sample3/4" Coldfeed
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79934 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River Transportation Laboratory (TL) Number858144
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-11-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-06-27-23
DIME Test ID: 2025-06-27-23-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-07-08

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Dacota Mei
Date of test: 07/02/2025
Cumulative Mass RetainedCumulative Percent Passing
5048.3 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
72.0 grams99 %
1100.0 grams78 %
1832.0 grams64 %
3049.0 grams40 %
506 grams
138.8 grams29 %
293.3 grams17 %
361.9 grams11 %
411.8 grams7 %
449.0 grams5 %
469.3 grams2.9 %
470.1 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/8/2025