Summary for Test 2025-06-02-90-3
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1000698 DEA: 024H0704 EFIS: 0218000074 |
|---|---|
| DIST-CO-RTE-PM | 02-LAS-139-0.74/11.0 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | PLACE HMA (TYPE A), TRAFFIC CONTROL SYSTEM, TRAFFIC STRIPE, RDWY EXC. |
| Location Description | LASSEN COUNTY NEAR SUSANVILLE FROM 0.1 MILE NORTH OF CHESTNUT STREET TO 2.6 MILES SOUTH OF HORSE LAKE ROAD |
| QA Service Level | 1 (Verified on 10/24/2024) |
Sample Information
| Sample Taken Date | 06/02/2025 | Sample Unique Key | 90 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2025 |
| Sample type | Acceptance | A brief description of the sample | 6 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28) |
| The quantity of what the sample constitutes | 10,000 tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | D79898 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Hat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA) | Transportation Laboratory (TL) Number | 996946 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-06-02-90
DIME Test ID: 2025-06-02-90-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-07-08
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 06/12/2025
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 1.58 mm
Maximum impression at 5000 passes (right wheel): 2.05 mm
Average impression at 5000 passes (left/right avg): 1.82 mm
Maximum impression at 10000 passes (left wheel): 1.8 mm
Maximum impression at 10000 passes (right wheel): 2.63 mm
Average impression at 10000 passes (left/right avg): 2.21 mm
Maximum impression at 15000 passes (left wheel): 2.14 mm
Maximum impression at 15000 passes (right wheel): 2.94 mm
Average impression at 15000 passes (left/right avg): 2.54 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Nf>15000,
SIP>15000
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| D79898, 996946, 02-4H0703, HWT | 734.80 KB | 07/08/2025 | 2025-06-02-90-3 | Info |
Test was verified on 7/8/2025 ✔