Summary for Test 2025-07-07-28-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000926
DEA: 061G8304
EFIS: 0624000171
DIST-CO-RTE-PM06-FRE-99-19.9/21.4
Award Date03/27/2025
Closeout Date11/10/2025
Work DescriptionREPLACE CONCRETE SLABS WITH HMA, COLD PLANE AND PLACE HMA (TYPE A).
Location DescriptionFRESNO COUNTY IN FRESNO FROM 0.1 MILE NORTH OF CALIFORNIA AVENUE OVERCROSSING TO 0.1 MILE SOUTH OF EL DORADO STREET OVERCROSSING
QA Service Level1 (Verified on 03/04/2025)

Sample Information

Sample Taken Date07/07/2025 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing07/07/2025 Sample typeQuality Assurance
A brief description of the sample3/4 cold feed and rap The quantity of what the sample constitutessampled @ 800T
From where was the sample collectedManufacturer First name of sampler or witnessed byJonathon
Last name of sampler or witnessed byChaney Title of samplerMREA
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Ashlan
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-20-0016
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number221534 Lot number1
Sublot number2 Aggregate Mix Number221534

Test Details

DIME Sample ID: 2025-07-07-28
DIME Test ID: 2025-07-07-28-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-07-08

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 07/08/2025
Cumulative Percent Passing
%
100 %
100 %
100 %
87 %
74 %
48 %
32 %
23 %
18 %
12 %
7 %
4.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/8/2025 ✔