Summary for Test 2025-06-24-54-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-3.5/6.8 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC). |
| Location Description | TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 06/24/2025 | Sample Unique Key | 54 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/24/2025 | Sample type | Acceptance |
| A brief description of the sample | Native Subgrade | The quantity of what the sample constitutes | 24.4 kg |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Gabriel |
| Last name of sampler or witnessed by | Ramirez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | I-15 NB North of Rancho California Rd On-Ramp, Roadway Widening, Sta 297+40 - 300+00 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-06-24-54
DIME Test ID: 2025-06-24-54-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-07-07
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 06/24/2025
Gage No.: 36636
Test No.: 1
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 1
Depth: 8"
Material No.: N/A
Material Type: Native Subgrade
Impact By: Gabriel Ramirez
Standard Count Density: 1720 g/cc
Count or Density 1: 1052 g/cc
Count or Density 2: 1102 g/cc
Count or Density 3: 1149 g/cc
Standard Count Moisture: 646 g/cc
Moisture Count 1: 67 g/cc
Moisture Count 2: 80 g/cc
Moisture Count 3: 61 g/cc
Sum of Count or Density: 3303 g/cc
Average of Count or Density: 1101 g/cc
Sum of Moisture Count: 208 g/cc
Average of Moisture Count: 69 g/cc
Count Ratio Density: 0.64
Count Ratio Moisture: 0.11
Calculated Percent Relative Compaction: 97.6 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%
Test was verified on 7/7/2025 ✔