Summary for Test 2025-06-24-53-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1000665
DEA: 081K4004
EFIS: 0819000031
DIST-CO-RTE-PM08-RIV-15-3.5/6.8
Award Date01/29/2025
Closeout DateNot set
Work DescriptionHMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC).
Location DescriptionTEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date06/24/2025 Sample Unique Key53
Date that the sample was received by the laboratory/organization performing the testing06/24/2025 Sample typeAcceptance
A brief description of the sampleNative Subgrade The quantity of what the sample constitutes25.5 kg
From where was the sample collectedJob Site First name of sampler or witnessed byGabriel
Last name of sampler or witnessed byRamirez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCTM 231 TEST LOCATION
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedI-15 NB North of Rancho California Rd On-Ramp, Roadway Widening, Sta 282+40 - 297+40
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-06-24-53
DIME Test ID: 2025-06-24-53-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-07-07

Test Results


Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 06/24/2025
Gage No.: 36636
Test No.: 1
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 7
Depth: 8"
Material No.: N/A
Material Type: Native Subgrade
Impact By: Gabriel Ramirez
Standard Count Density: 1720 g/cc
Count or Density 1: 997 g/cc
Count or Density 2: 1086 g/cc
Count or Density 3: 1056 g/cc
Count or Density 4: 970 g/cc
Count or Density 5: 1005 g/cc
Standard Count Moisture: 646 g/cc
Moisture Count 1: 83 g/cc
Moisture Count 2: 72 g/cc
Moisture Count 3: 77 g/cc
Moisture Count 4: 69 g/cc
Moisture Count 5: 77 g/cc
Sum of Count or Density: 5114 g/cc
Average of Count or Density: 1023 g/cc
Sum of Moisture Count: 378 g/cc
Average of Moisture Count: 76 g/cc
Count Ratio Density: 0.59
Count Ratio Moisture: 0.12
Calculated Percent Relative Compaction: 97.2 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%

Test was verified on 7/7/2025 ✔