Summary for Test 2025-06-11-69-8

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000751
DEA: 060Y1704
EFIS: 0619000004
DIST-CO-RTE-PM06-KIN-41-0.0/15.5
Award Date03/03/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, OVERLAY HMA AND RHMA.
Location DescriptionKINGS COUNTY NEAR KETTLEMAN CITY FROM THE KERN COUNTY LINE TO 0.8 MILE SOUTH OF ROUTE 5
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date06/11/2025 Sample Unique Key69
Date that the sample was received by the laboratory/organization performing the testing06/19/2025 Sample typeQuality Assurance
A brief description of the samplePG 64-10 The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byO
Last name of sampler or witnessed byS Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSierra Pacific - Avenal
Transportation Laboratory (TL) Number027376 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-06-11-69
DIME Test ID: 2025-06-11-69-8
Testing Lab: WSP USA - Phoenix
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-07-03

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: WSP
Date of test: 07/01/2025
Time of test: 09:16 HH:MM
Test Temperature: 135.5 C
Speed: 200 rpm
Spindle size: .463 in
Torque: 18.8 %
Viscosity reading #1 (A) : 235 cP
Viscosity reading #2 (B) : 235 cP
Viscosity reading #3 (C): 235 cP
Average viscosity : 0.235 Pa-s
General comments (publicly viewable) (Max 1000 characters): Viscosity @135C

Test was verified on 7/3/2025 ✔