Summary for Test 2025-06-30-23-2
Test performed: ASTM C1611-21Project Information
| Project Identifiers | Project ID: 1000015 DEA: 033H8304 EFIS: 0318000075 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-49-3.5/7.5 |
| Award Date | 01/06/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT SIDEWALKS, CURB RAMPS AND DRAINAGE FACILITIES. CONSTRUCT PEDESTRIAN BRIDGE |
| Location Description | PLACER COUNTY IN AND NEAR AUBURN FROM 0.3 MILE NORTH OF ROUTE 80/49 SEPARATION TO 0.1 MILE NORTH OF DRY CREEK ROAD |
| QA Service Level | 1 (Verified on 01/18/2024) |
Sample Information
| Sample Taken Date | 06/30/2025 | Sample Unique Key | 23 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2025 |
| Sample type | Quality Control | A brief description of the sample | 1 cubic foot |
| The quantity of what the sample constitutes | 1 cubic foot | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Patrick | Last name of sampler or witnessed by | Baddu |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | ConFab Lathrop | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 98NV20AF |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 12830 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Fabrication Yard | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-06-30-23
DIME Test ID: 2025-06-30-23-2
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating Concrete
Test Release Date: 2025-08-18
Test Results
What unit system is used for measurements?: inches
Input Type: Calculated
Tester's full name: Patrick Wright
Date of test: 06/30/2025
Filling the mold procedure: Filling Procedure B (Inverted Mold)
Diameter 1: 23 in
Diameter 2: 23 in
Visual Stability Index: 0
Slump Flow: 23 in
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2025 ✔