Summary for Test 2025-06-26-58-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000117
DEA: 020J0104
EFIS: 0219000044
DIST-CO-RTE-PM02-TEH-99-4.2/4.8
Award Date07/11/2024
Closeout DateNot set
Work DescriptionPLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location DescriptionTEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date06/26/2025 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2025
Sample typeProduction Start-Up A brief description of the sample1 Bag RAP
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79923B Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River, Orland Transportation Laboratory (TL) Number858140
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceOrland Plant
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2025-06-26-58
DIME Test ID: 2025-06-26-58-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-02

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Dacota Mei
Date of test: 06/30/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3026.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 4638.0 g
Mass of HMA Sample prior to ignition: 1611.3 g
Mass Loss: 99.5 g
Mass of aggregate remaining after ignition: 1511.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.99 %
General comments (publicly viewable) (Max 1000 characters): Pbr (uncorrected)=5.99%

Test was verified on 7/2/2025