Summary for Test 2025-06-02-74-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000683
DEA: 11056404
EFIS: 1124000359
DIST-CO-RTE-PM11-SD-11-0.6/2.7
Award Date12/20/2024
Closeout Date01/06/2026
Work DescriptionPERFORM GRADING, CONSTRUCT DRAINAGE FACILITIES, SIGNS AND STRIPING.
Location DescriptionSAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 0.2 MILE EAST OF SIEMPRE VIVA ROAD OVERCROSSING
QA Service Level1 (Verified on 01/17/2025)

Sample Information

Sample Taken Date06/02/2025 Sample Unique Key74
Date that the sample was received by the laboratory/organization performing the testing06/02/2025 Sample typeQuality Assurance
A brief description of the samplePlant Sample The quantity of what the sample constitutes3 bags
From where was the sample collectedSource First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byCordero Title of samplerTET
Telephone number of sampler6199366795 Laboratory sample identification25-06-02-74-S
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociated Otay
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Provided
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number558037 Lot number
Sublot number Aggregate Mix Number

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
2025-07-13: PCC Aggregates (Size 1"): Sieve Analysis12025-06-02-74-1

Test Details

DIME Sample ID: 2025-06-02-74
DIME Test ID: 2025-06-02-74-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-07-11

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 07/11/2025
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
10729 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
487.0 grams95 %
3665.0 grams66 %
9160.0 grams15 %
10474.0 grams2 %
10655.0 grams1 %
41 grams
2.7 grams1 %
4.9 grams1 %
8.0 grams1 %
13.4 grams1 %
20.5 grams1 %
25.0 grams0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/11/2025 ✔