Summary for Test 2025-06-26-17-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 1000682 DEA: 09379104 EFIS: 0919000005 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-91.6/100.8 |
| Award Date | 02/20/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS. |
| Location Description | INYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168 |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 06/26/2025 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/26/2025 |
| Sample type | Acceptance | A brief description of the sample | 3/4” HMA A R-18 SP PG58-34M |
| The quantity of what the sample constitutes | 1 box HMA | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dylan | Last name of sampler or witnessed by | Carapazza |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | HMA-15 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Road and Highway Builders | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2025-06-26-17
DIME Test ID: 2025-06-26-17-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-07-01
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 07/01/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7310.5 grams
Mass of oven-dry sample in air for Sample 1: 2239.1 grams
Mass of container filled with the sample and water for Sample 1: 8647.5 grams
Temperature of Water: 77.4 °F
Specific Gravity for Sample 1: 2.482
Theoretical maximum density at 25°C (77°F): 154.5 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): HMA-15
Test was verified on 7/1/2025 ✔