Summary for Test 2025-07-01-1-2
Test performed: AASHTO T48-18Project Information
| Project Identifiers | Project ID: 1000682 DEA: 09379104 EFIS: 0919000005 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-91.6/100.8 |
| Award Date | 02/20/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS. |
| Location Description | INYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168 |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 07/01/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/01/2025 |
| Sample type | Quality Control | A brief description of the sample | Modified Asphalt Binder |
| The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Brent | Last name of sampler or witnessed by | skovly |
| Title of sampler | Telephone number of sampler | 7758356366 | |
| Laboratory sample identification | 2025-07-01 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | PNAC LLC, Marathon Petroleum | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | 5 | |
| Time of sample | 0500 | HMA Supplier | |
| Certified Asphalt Supplier | Paramount Nevada Asphalt(PNAC) LLC - Fernley NV | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-07-01-1
DIME Test ID: 2025-07-01-1-2
Testing Lab: PNAC LLC
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2025-07-01
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Brent Skovly
Date of test: 07/01/2025
Observed Flash Point: 327 C
Ambient Barometric Pressure: 759.46 mmHg
Cleveland Open-Cup Flash Point in Celsius: 327 C
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/1/2025 ✔