Summary for Test 2025-06-20-1-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995254
DEA: 040P9204
EFIS: 0418000026
DIST-CO-RTE-PM04-ALA-680-6.4/6.6
Award Date12/20/2024
Closeout Date03/23/2026
Work DescriptionHMA AND RHMA SURFACING, DECK REPAIR, POLYESTER OVERLAY AND JOIN SEALS
Location DescriptionALAMEDA COUNTY IN FREMONT FROM 0.1 MILE SOUTH OF MISSION SAN JOSE 680/238 SEPARATION TO 0.3 MILE NORTH OF MISSION SAN JOSE 680/238 SEPARATION
QA Service Level1 (Verified on 10/17/2023)

Sample Information

Sample Taken Date06/20/2025 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing06/24/2025 Sample typeQuality Assurance
A brief description of the sampleLenton form savers The quantity of what the sample constitutes50 lbs
From where was the sample collectedFabricator First name of sampler or witnessed byJordan
Last name of sampler or witnessed byJarosz Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartinez Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar ManufacturerMartinez Steel
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelLenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)M0341 Rebar Heat Number(s)450224
Rebar Size 2 Coupler Unique IDST-17-05

Test Details

DIME Sample ID: 2025-06-20-1
DIME Test ID: 2025-06-20-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-06-30

Test Results


Number of Samples: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/30/2025
UTM: NA
Halo ID: na
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11150.310.0052931094500service spliceKleinfelder
22150.3100003032098000service spliceKleinfelder
33150.3100003017097500service spliceKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/30/2025 ✔