Summary for Test 2017-11-01-7-4

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 9999
DEA: 00000000
EFIS: 0000000000
COOP: 99999333399
MINOR: 333333
Permit Numbers: 555555 0400NRT0000
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level1 (Verified on 04/05/2013)

Sample Information

Sample Taken Date11/01/2017 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing11/01/2017 Sample typeVerification
A brief description of the samplefor JMF verification The quantity of what the sample constitutes1
From where was the sample collectedManufacturer First name of sampler or witnessed byThinh
Last name of sampler or witnessed byNguyen Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameMustang
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)123456
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedtesting for JMF Verification
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2017-11-01-7
DIME Test ID: 2017-11-01-7-4
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2017-11-08

Test Results


Input Type: Calculated
Tester's full name: Thinh Nguyen
Date of test: 11/01/2017
Grading designation: A
Percent loss after 100 revolutions: 3 %
Percent loss after 500 revolutions: 15 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/1/2017 ✔