Summary for Test 2025-05-13-73-3
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1000245 DEA: 072XN104 EFIS: 0724000222 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-150- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Retaining wall repair due to landslide emergency at Route 150 in Santa Paula. |
| Location Description | Route 150 in Santa Paula. |
| QA Service Level | 1 (Verified on 04/05/2024) |
Sample Information
| Sample Taken Date | 05/13/2025 | Sample Unique Key | 73 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/19/2025 |
| Sample type | Acceptance | A brief description of the sample | 4X8 PCC cylinders |
| The quantity of what the sample constitutes | 130 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Armando | Last name of sampler or witnessed by | Serratos |
| Title of sampler | Assistant Structure Representative | Telephone number of sampler | |
| Laboratory sample identification | 25-159 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | RSR DEMO | Transportation Laboratory (TL) Number | 116160 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SL590330 |
|---|---|---|---|
| The truck number from where the sample was collected | NA | The batch plant ticket number from where the sample was collected | NA |
| Concrete batch plant | NA | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-05-13-73
DIME Test ID: 2025-05-13-73-3
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-06-28
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 06/10/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 65467 lb
Maximum load on cylinder 2: 74053 lb
Maximum load on cylinder 3: 73666 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 5158.9 psi
Compressive strength of cylinder 2: 5863.3 psi
Compressive strength of cylinder 3: 5832.6 psi
Compressive strength (to nearest 10 psi): 5620 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/28/2025 ✔