Summary for Test 2025-06-17-99-1
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 210409 DEA: 08432724 EFIS: 0800020178 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-8-RIV-15-6.4/9.7 |
| Award Date | 05/01/2023 |
| Closeout Date | Not set |
| Work Description | Collector/distributor system, new on-ramps, bridges, RW, sound walls, drainage, signal and lighting, signage, freeway widening |
| Location Description | I-15 from Winchester Road to I-215 Junction in Temecula |
| QA Service Level | 2 (Verified on 06/24/2021) |
Sample Information
| Sample Taken Date | 06/17/2025 | Sample Unique Key | 99 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/19/2025 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Jason |
| Last name of sampler or witnessed by | Buskoy | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | All American Asphalt Perris | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2025-06-17-99
DIME Test ID: 2025-06-17-99-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2025-07-17
Test Results
ASTM Thermometer used?: C
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 06/25/2025
Softening Point Sample 1: 63 C
Softening Point Sample 2: 63 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2025 ✔