Summary for Test 2025-04-09-75-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 995038 DEA: 07347004 EFIS: 0718000092 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-9.6/T32.1 |
| Award Date | 09/28/2023 |
| Closeout Date | Not set |
| Work Description | DRAINAGE SYSTEM RESTORATION. |
| Location Description | LOS ANGELES COUNTY IN LONG BEACH AND PASADENA AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/03/2023) |
Sample Information
| Sample Taken Date | 04/09/2025 | Sample Unique Key | 75 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2025 |
| Sample type | Acceptance | A brief description of the sample | Structural Backfill |
| The quantity of what the sample constitutes | 37 cu. yd. | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Philip | Last name of sampler or witnessed by | Maquiran |
| Title of sampler | MREA | Telephone number of sampler | (213) 358-1518 |
| Laboratory sample identification | 25-1185 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | DOJA Inc. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | From various location at SBF | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-04-09-75
DIME Test ID: 2025-04-09-75-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-06-25
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 04/09/2025
Sum of Count or Density: 6.21 g/cc
Average of Count or Density: 2.07 g/cc
Sum of Moisture Count: 0.62 g/cc
Average of Moisture Count: 0.21 g/cc
Calculated Percent Relative Compaction: 96.3 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/25/2025 ✔