Summary for Test 2025-04-18-65-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date04/18/2025 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/19/2025
Sample typeAcceptance A brief description of the sampleISR-RS 6"X6"X21" Beam
The quantity of what the sample constitutes120 CY approximate From where was the sample collectedJob Site
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of samplerMREA Telephone number of sampler(213) 358-1518
Laboratory sample identification25-1259 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMYERS Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberVCTS675
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plantMyers The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-04-18-65
DIME Test ID: 2025-04-18-65-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2025-06-25

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 04/21/2025
Identification number: 25-1259
Width of specimen: 6.0625 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 6.125 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.1875 inch
Depth of specimen 3: 5.1875 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 6864 lb
Maximum load applied 2: 7089 lb
Maximum load applied 3: 7557 lb
Curing history and apparent moisture condition of the specimen: Damp
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 580 psi
Modulus of rupture 2: 590 psi
Modulus of rupture 3: 610 psi
Modulus of rupture average: 590 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/25/2025