Summary for Test 2025-05-28-58-4
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 995242 DEA: 060Y1304 EFIS: 0619000010 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-33-40.4/59.3 |
| Award Date | 06/20/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE, PLACE HMA AND RHMA-G, AND REPLACE CULVERTS. |
| Location Description | KERN COUNTY ABOUT 8 MILES NORTH OF MCKITTRICK FROM CYMRIC WASH BRIDGE TO 0.8 MILE SOUTH OF ROUTE 46 |
| QA Service Level | 1 (Verified on 09/03/2024) |
Sample Information
| Sample Taken Date | 05/28/2025 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/29/2025 |
| Sample type | Acceptance | A brief description of the sample | Box # 1 |
| The quantity of what the sample constitutes | 18 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Adam | Last name of sampler or witnessed by | Mahmoud |
| Title of sampler | Structure Representative | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Golden empire concrete - Bakersfield | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | NCT09014 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | BACK OF THE TRUCK | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-05-28-58
DIME Test ID: 2025-05-28-58-4
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-06-25
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 06/25/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 63890 lb
Maximum load on cylinder 2: 61140 lb
Maximum load on cylinder 3: 63490 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5082.7 psi
Compressive strength of cylinder 2: 4864.0 psi
Compressive strength of cylinder 3: 5050.9 psi
Compressive strength (to nearest 10 psi): 5000 psi
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-0Y1304_37000_250528_28D | 222.13 KB | 06/25/2025 | 2025-05-28-58-4 | Info |
Test was verified on 6/25/2025 ✔