Summary for Test 2025-05-17-17-2
Test performed: AASHTO T240-17Project Information
| Project Identifiers | Project ID: 1000346 DEA: 081N6904 EFIS: 0823000037 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-36.6/37.0 |
| Award Date | 01/23/2025 |
| Closeout Date | 07/22/2025 |
| Work Description | HMA, ROADWAY EXCAVATION, CLASS 2 AB, REMOVE BASE & SURFACING, RHMA. |
| Location Description | RIVERSIDE COUNTY IN CORONA FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF CAJALCO ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 05/17/2025 | Sample Unique Key | 17 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/21/2025 | Sample type | Verification |
| A brief description of the sample | Asphalt Binder Sample | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Drew |
| Last name of sampler or witnessed by | STALLINGS | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2025-05-17-17
DIME Test ID: 2025-05-17-17-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-07-02
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Sunday Agude
Date of test: 06/25/2025
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 168.834 grams
Mass of empty container #2: 171.470 grams
Mass of container #1 before test (m1i): 203.973 grams
Mass of container #2 before test (m2i): 206.478 grams
Mass of container #1 after test (m1f): 203.941 grams
Mass of container #2 after test (m2f): 206.441 grams
Average mass change: -0.098 percent
General comments (publicly viewable) (Max 1000 characters): -0.098 + 0.006 = -0.092
Test was verified on 7/2/2025 ✔