Summary for Test 2025-05-28-46-7
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 1001283 DEA: 010Q0304 EFIS: 0125000108 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-36-27.0/27.9 |
| Award Date | 02/21/2025 |
| Closeout Date | Not set |
| Work Description | Repair Storm Damage |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 05/28/2025) |
Sample Information
| Sample Taken Date | 05/28/2025 | Sample Unique Key | 46 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/02/2025 |
| Sample type | Verification | A brief description of the sample | PG 58-22, FEEDLINE |
| The quantity of what the sample constitutes | 1 can | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Attureo |
| Title of sampler | Tester | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mercer Fraser Dinsmore | Transportation Laboratory (TL) Number | 00000 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-05-28-46
DIME Test ID: 2025-05-28-46-7
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-06-25
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas
Date of test: 06/13/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.105 grams
Mass of container #2 before test (m2i): 210.154 grams
Mass of container #1 after test (m1f): 202.938 grams
Mass of container #2 after test (m2f): 209.990 grams
Mass of empty container #1: 168.091 grams
Mass of empty container #2: 175.445 grams
Mass correction factor: 0.030
Average mass change: -0.445 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change
Test was verified on 6/25/2025 ✔