Summary for Test 2025-06-09-75-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000029
DEA: 101K4304
EFIS: 1021000096
DIST-CO-RTE-PM10-MER-165-16.5/26.8
Award Date06/26/2024
Closeout DateNot set
Work DescriptionRHMA (GAP GRADED) AND FULL DEPTH RECYCLING- CEMENT.
Location DescriptionMERCED COUNTY NEAR LOS BANOS FROM 1.5 MILES NORTH OF WOLFSEN ROAD TO 0.1 MILE SOUTH OF ROUTE 140
QA Service Level1 (Verified on 01/17/2024)

Sample Information

Sample Taken Date06/09/2025 Sample Unique Key75
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/10/2025
Sample typeQuality Assurance A brief description of the sample1/2 RHMA PG 64-16
The quantity of what the sample constitutes8 Boxes From where was the sample collectedManufacturer
First name of sampler or witnessed byTimothy Last name of sampler or witnessed byTrefz
Title of samplerLab Technician Telephone number of sampler
Laboratory sample identification25-H-125 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSanta Fe Aggregate Winton Transportation Laboratory (TL) Number1K43205
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number2
Sublot number5 HMA Mix Number25J07
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-06-09-75
DIME Test ID: 2025-06-09-75-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-06-19

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 06/11/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1593.2 g
Mass Loss: 119.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.53 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/19/2025