Summary for Test 2025-05-22-70-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 995450 DEA: 09368004 EFIS: 0917000011 |
|---|---|
| DIST-CO-RTE-PM | 09-MNO-395-91.6/93.4 |
| Award Date | 02/29/2024 |
| Closeout Date | Not set |
| Work Description | HOT MIX ASPHALT (TYPE A), RAIL ELEMENT WALL, AND ROADWAY EXCAVATION. |
| Location Description | MONO COUNTY ABOUT 16 MILES NORTH OF BRIDGEPORT FROM BURCHAM FLAT ROAD TO 0.3 MILE SOUTH OF ROUTE 108 |
| QA Service Level | 1 (Verified on 01/18/2024) |
Sample Information
| Sample Taken Date | 05/22/2025 | Sample Unique Key | 70 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/26/2025 |
| Sample type | Acceptance | A brief description of the sample | 6x12 PCC Cylinders |
| The quantity of what the sample constitutes | 4 PCC Cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Puente |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | 4606 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | 7-11 Materials Bishop | Transportation Laboratory (TL) Number | PCC-03 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Little Walker Cattle Guard | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | 1st part of Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-05-22-70
DIME Test ID: 2025-05-22-70-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-06-19
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 06/19/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 124620 lb
Maximum load on cylinder 2: 123710 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4408.2 psi
Compressive strength of cylinder 2: 4376.0 psi
Compressive strength (to nearest 10 psi): 4390 psi
General comments (publicly viewable) (Max 1000 characters): Little Walker Cattle Guard
Test was verified on 6/19/2025 ✔