Summary for Test 2024-10-23-65-3
Test performed: ASTM D638-Dec14Project Information
| Project Identifiers | Project ID: 1000284 DEA: 041Y5004 EFIS: 0422000498 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-280-R2.7/R4.2L |
| Award Date | 06/17/2024 |
| Closeout Date | Not set |
| Work Description | PLACE POLYESTER CONCRETE OVERLAY, AND REPLACE JOINT SEAL. |
| Location Description | THE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS FROM MONTEREY BOULEVARD ON-RAMP OVERCROSSING TO ROUTE 280/101 SEPARATION |
| QA Service Level | 1 (Verified on 07/15/2024) |
Sample Information
| Sample Taken Date | 10/23/2024 | Sample Unique Key | 65 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2024 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can / PPC 1121 RESIN |
| The quantity of what the sample constitutes | 10 Tankers | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
| Laboratory sample identification | 000143KBP | Linked DIME Sample ID | 000143KBP |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Polyester | Mfg. Lot Number(s) | AZ4J01628S |
|---|---|---|---|
| Batch number | AZ4J01628S | Mix number | AZ4J01628S |
Test Details
DIME Sample ID: 2024-10-23-65
DIME Test ID: 2024-10-23-65-3
Testing Lab: Future Labs, LLC
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2025-06-18
Test Results
Number of specimens tested: 6
Input Type: Measured
Tester's full name: Alex Hamilton
Date of test: 06/11/2025
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.51 in
Sample 1 Thickness: 0.256 in
Sample 1 Area: 0.1306 in^2
Sample 1 Ultimate Strength Actual: 329 lbs
Sample 1 percent elongation: 50 %
Sample 1 Time: 0 MM:SS
Sample 2 Width: 0.503 in
Sample 2 Thickness: 0.237 in
Sample 2 Area: 0.1192 in^2
Sample 2 Ultimate Strength Actual: 299 lbs
Sample 2 percent elongation: 51 %
Sample 2 Time: 0 MM:SS
Sample 3 Width: 0.504 in
Sample 3 Thickness: 0.231 in
Sample 3 Area: 0.1164 in^2
Sample 3 Ultimate Strength Actual: 288 lbs
Sample 3 percent elongation: 50 %
Sample 3 Time: 0 MM:SS
Sample 4 Width: 0.505 in
Sample 4 Thickness: 0.228 in
Sample 4 Area: 0.1151 in^2
Sample 4 Ultimate Strength Actual: 292 lbs
Sample 4 percent elongation: 54 %
Sample 4 Time: 0 MM:SS
Sample 5 Width: 0.505 in
Sample 5 Thickness: 0.231 in
Sample 5 Area: 0.1167 in^2
Sample 5 Ultimate Strength Actual: 291 lbs
Sample 5 percent elongation: 53 %
Sample 5 Time: 0 MM:SS
Sample 6 Width: 0.509 in
Sample 6 Thickness: 0.233 in
Sample 6 Area: 0.1186 in^2
Sample 6 Ultimate Strength Actual: 298 lbs
Sample 6 percent elongation: 53 %
Sample 6 Time: 0 MM:SS
Sample 1 Ultimate strength: 2519.1 psi
Sample 2 Ultimate strength : 2508.4 psi
Sample 3 Ultimate strength: 2474.2 psi
Sample 4 Ultimate strength: 2536.9 psi
Sample 5 Ultimate strength: 2493.6 psi
Sample 6 Ultimate strength : 2512.6 psi
Ultimate Strength Average: 2507 psi
Percent Elongation Average: 52 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/18/2025 ✔